Controls and Features
6 Rev 41153-20100604 E
Power Panel
(1) Intelligauge Three mode digital
meter for running hours, voltage and hertz.
(2) Circuit Breakers Protects the
generator against electrical overload.
(3) Engine SwitchPress the switch to
the “Start” position to start the generator.
Flip to the “Off” position to turn off the
generator.
(4) 120 V 30 A Twist-Lock – Protected
by a 25 A circuit breaker. This receptacle
powers 120 Volt AC, 60 Hz, single phase
loads requiring up to 23 Amps or 2750 watts
of power.
(5) 120/240 V 30 A Twist-Lock
Protected by a 25 A double throw circuit
breaker on each 120 Volt leg of the
receptacle. This receptacle powers 240 Volt
AC, 60 Hz, single phase loads requiring up
to 25 A or 5500 Watts of power. If an L14-
30P plug is wired for only one 120 Volt leg
(3-wire connection) then this receptacle
powers 120 Volt AC, 60 Hz, single phase
loads requiring up to 23 A or 2750 Watts of
power.
(6) 120 V 20 A Duplexprotected by a
20 A circuit breaker. Use this duplex to
operate 120 Volt AC, single phase, 60 Hz
loads requiring up to 20 A 0r 2400 Watts of
power.
(7) Ground Terminal Consult an
electrician for local grounding regulations.